VIPA FM 050-1BB30 8DO-24VDC
VIPA FM 050-1BB30 8DO-24VDC
050-1BB30 – Function modules | Counter modules
Order no. | 050-1BB30 |
Type | FM 050 |
Module ID | 08C4 388B |
General information | |
Note | – |
Features | 2x Counter 32 Bit (AB) DC 24 V Up to 400 kHz |
Current consumption/power loss | |
Current consumption from backplane bus | 75 mA |
Power loss | 0.9 W |
Technical data digital inputs | |
Number of inputs | 4 |
Cable length, shielded | 100 m |
Cable length, unshielded | – |
Rated load voltage | DC 20.4…28.8 V |
Reverse polarity protection of rated load voltage | – |
Current consumption from load voltage L+ (without load) | 15 mA |
Rated value | DC 20.4…28.8 V |
Input voltage for signal “0” | DC 0…5 V |
Input voltage for signal “1” | DC 15…28.8 V |
Input voltage hysteresis | – |
Signal logic input | – |
Frequency range | – |
Input resistance | – |
Input current for signal “1” | 3 mA |
Connection of Two-Wire-BEROs possible | |
Max. permissible BERO quiescent current | 0.5 mA |
Input delay of “0” to “1” | 0.8 µs |
Input delay of “1” to “0” | 0.8 µs |
Number of simultaneously utilizable inputs horizontal configuration | 4 |
Number of simultaneously utilizable inputs vertical configuration | 4 |
Input characteristic curve | IEC 61131-2, type 1 |
Initial data size | 12 Byte |
Technical data digital outputs | |
Number of outputs | – |
Cable length, shielded | – |
Cable length, unshielded | – |
Rated load voltage | – |
Current consumption from load voltage L+ (without load) | – |
Output delay of “0” to “1” | – |
Output delay of “1” to “0” | – |
Minimum load current | – |
Lamp load | – |
Parallel switching of outputs for redundant control of a load | – |
Parallel switching of outputs for increased power | – |
Actuation of digital input | – |
Switching frequency with resistive load | – |
Switching frequency with inductive load | – |
Switching frequency on lamp load | – |
Internal limitation of inductive shut-off voltage | – |
Short-circuit protection of output | – |
Trigger level | – |
Number of operating cycle of relay outputs | – |
Switching capacity of contacts | – |
Output data size | 4 Byte |
Technical data counters | |
Number of counters | 2 |
Counter width | 32 Bit |
Maximum input frequency | 100 kHz |
Maximum count frequency | 400 kHz |
Mode incremental encoder | |
Mode pulse / direction | |
Mode pulse | – |
Mode frequency counter | – |
Mode period measurement | – |
Gate input available | – |
Latch input available | – |
Reset input available | – |
Counter output available | – |
Status information, alarms, diagnostics | |
Status display | yes |
Interrupts | no |
Process alarm | no |
Diagnostic interrupt | no |
Diagnostic functions | no |
Diagnostics information read-out | possible |
Module state | green LED |
Module error display | red LED |
Channel error display | none |
FM 050-1BB30 8DO-24VDC VIPA