Description
SICK RLY3-OSSD100
SICK RLY3-OSSD100
- Features
Applications Output expansion module for OSSDs Compatible sensor types Safety sensors with OSSDs
- Safety-related parameters
Safety integrity level SIL3 (IEC 61508) SILCL3 (IEC 62061)
Category Category 4 (ISO 13849-1) Performance level PL e (ISO 13849-1) PFHD (mean probability of a dangerous failure per hour) 1.0 x 10-9 TM (mission time) 20 years (ISO 13849-1) Stop category 0 (IEC 60204-1)
- Functions
Path for external device monitoring (EDM) ✔
- Interfaces
Connection type Front connector with spring terminals Inputs 2 safety inputs Outputs 2 enabling current paths (safe) 1 feedback current path (for use as external device monitoring, not safe)
Display elements LEDs
- Electrical data – Operating data
Voltage supply Passive (no active voltage supply) Power consumption (input circuits) ≤ 1.5 W (DC)
- Electrical data – Safety inputs
Number 2 Input voltage HIGH 24 V DC (15 V … 30 V) LOW 0 V DC (–3 V … 5 V) Input current ≤ 50 mA Test pulse width ≤ 1 ms Test pulse rate ≤ 10 Hz
- Electrical data – Enabling current paths
Response time 12 ms Number 2 Type of output N/O contacts, positively guided Contact material Silver alloy, gold flashed Switching voltage 10 V AC … 230 V AC 10 V DC … 230 V DC
Switching current 10 mA … 6 A Total current 12 A Mechanical life 1 x 107 switching cycles Overvoltage category III (EN 60664-1) Rated impulse withstand voltage Uimp 6 kV (EN 60664-1)
Reviews
There are no reviews yet.