- Performance
Pulses per revolution 2,048 1) Measuring step 90° electric/pulses per revolution Measuring step deviation at binary number of lines ± 0.008° Error limits ± 0.05° - 1) See maximum revolution range.
- Interfaces
Communication interface Incremental Communication Interface detail TTL / RS-422 Number of signal channels 6-channel Initialization time 40 ms Output frequency ≤ 600 kHz Load current ≤ 30 mA Operating current 40 mA (without load)
- Electrical data
Connection type Cable, 8-wire, universal, 1.5 m 1) Supply voltage 4.5 … 5.5 V Reference signal, number 1 Reference signal, position 90°, electric, logically gated with A and B Short-circuit protection of the outputs ✔ 2) MTTFd: mean time to dangerous failure 300 years (EN ISO 13849-1) 3) - 1) The universal cable connection is positioned so that it is possible to lay it without bends in a radial or axial direction.
- 2) Short-circuit opposite to another channel, US or GND permissable for maximum 30 s.
- 3) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40°C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.
- Mechanical data
Mechanical design Blind hollow shaft Shaft diameter 12 mm Weight + 0.2 kg Shaft material Stainless steel Flange material Aluminum Housing material Aluminum die cast Start up torque 0.8 Ncm (+20 °C) Operating torque 0.6 Ncm (+20 °C) Permissible movement static ± 0.3 mm (radial) ± 0.5 mm (axial)
Permissible movement dynamic ± 0.2 mm (radial) ± 0.1 mm (axial)
Operating speed ≤ 6,000 min⁻¹ 1) Moment of inertia of the rotor 40 gcm² Bearing lifetime 3.6 x 10^10 revolutions Angular acceleration ≤ 500,000 rad/s² - 1) Allow for self-heating of 3.3 K per 1,000 rpm when designing the operating temperature range.