SICK CFS50-AZZ0-S04
SICK CFS50-AZZ0-S04
- Features
Specialty Stranded cable 400 mm (2061880) inlcuded in delivery scope, plug in shaft
- Performance
Number of lines per revolution 1,024 1) Measuring step 90° /number of lines Commutation signals 3 pole pairs (See diagram, different commutation on request) Reference signal, number 1 Reference signal, position 90° electric, logically gated with A and B Operating speed ≤ 6,000 min⁻¹ - 1) Number of lines from 1 … 1,000 and > 4,096 … 65,536 on request.
- Interfaces
Communication interface Incremental
- Electrical data
Connection type Stranded wire, 15-pin, radial Supply voltage 4.5 V DC … 5.5 V DC Power consumption 60 mA 1) Maximum output frequency ≤ 820 kHz MTTF: mean time to dangerous failure 355 years (EN ISO 13849) 2) - 1) Without load.
- 2) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 60°C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.
- Mechanical data
Shaft version Plug-in shaft Flange type / stator coupling Rubber support Dimensions See dimensional drawing Weight 0.1 kg Moment of inertia of the rotor 10 gcm² Operating speed 12,000 min⁻¹ Angular acceleration ≤ 200,000 rad/s² Operating torque 0.2 Ncm Start up torque 0.4 Ncm Permissible movement of the drive element, static ± 0.75 mm axial Permissible movement of the drive element, dynamic ± 0.1 mm radial ± 0.2 mm axial
Angular motion perpendicular to the rotational axis, static ± 0.005 mm/mm Angular motion perpendicular to the rotational axis, dynamic ± 0.0025 mm/mm Life of ball bearings 3.6 x 109 revolutions
Reviews