Description
LEUZE HRT 46B/66-S122
LEUZE HRT 46B/66-S122
Type | HRT 46B/66-S12 | |
---|---|---|
Functions | Background suppression | |
Min. operating voltage | 10 V DC | |
Max. operating voltage | 30 V DC | |
Operating voltage | 10 – 30 V DC | |
Connector | M12 (4-pin) | |
Transmitter type | LED IR | |
Max. range | 2500 mm | |
IP rating | IP67/IP69K | |
Width | 18.5 mm | |
Height | 75 mm | |
Depth | 43.4 mm | |
Dim | (W x H x D) 18.5 x 75 x 43.4 mm | |
Product type | Retroreflective photo sensor |
Technical specifications
Optical data Infrared light
Type. Limit scanning range (white 90%) 1)
1) type. Limit scanning distance: max. achievable scanning distance for bright objects (white 90%)
0 … 2,500mm
Operating range 2)
2) Operating range: recommended range for objects of different remission
see tables
Adjustment range 120 … 2500mm
light source 3)
3) Average service life 100,000 hours at an ambient temperature of 25°C
LED (alternating light)
Wavelength 850nm
timing
Switching frequency transistor: 200Hz, relay: 20Hz
Response time transistor: 2.5ms, relay: 25ms
Ready delay ≤ 100ms
electrical data
with transistor switching outputs
Operating voltage UB 4)
4) For UL applications: only for use in “Class 2” circuits
10 … 30VDC (including residual ripple)
Residual ripple ≤ 15% of UB
No-load current ≤ 30mA
Switching output …/66. … 2 push-pull (push-pull) switching outputs 5)
Pin 2: PNP dark switching, NPN light switching
Pin 4: PNP light switching, NPN dark switching
5) The push-pull (push-pull) switching outputs must not be connected in parallel
…/44. … 2 PNP switching outputs
Pin 2: PNP dark switching, Pin 4: PNP light switching
…/4. … PNP switching output, pin 4: PNP light switching
…/4D. … PNP switching output, pin 4: PNP dark switching
Signal voltage high/low ≥ (UB-2V)/≤ 2V
Output current max. 100mA
Optical data Infrared light
Type. Limit scanning range (white 90%) 1)
1) type. Limit scanning distance: max. achievable scanning distance for bright objects (white 90%)
0 … 2,500mm
Operating range 2)
2) Operating range: recommended range for objects of different remission
see tables
Adjustment range 120 … 2500mm
light source 3)
3) Average service life 100,000 hours at an ambient temperature of 25°C
LED (alternating light)
Wavelength 850nm
timing
Switching frequency transistor: 200Hz, relay: 20Hz
Response time transistor: 2.5ms, relay: 25ms
Ready delay ≤ 100ms
electrical data
with transistor switching outputs
Operating voltage UB 4)
4) For UL applications: only for use in “Class 2” circuits
10 … 30VDC (including residual ripple)
Residual ripple ≤ 15% of UB
No-load current ≤ 30mA
Switching output …/66. … 2 push-pull (push-pull) switching outputs 5)
Pin 2: PNP dark switching, NPN light switching
Pin 4: PNP light switching, NPN dark switching
5) The push-pull (push-pull) switching outputs must not be connected in parallel
…/44. … 2 PNP switching outputs
Pin 2: PNP dark switching, Pin 4: PNP light switching
…/4. … PNP switching output, pin 4: PNP light switching
…/4D. … PNP switching output, pin 4: PNP dark switching
Signal voltage high/low ≥ (UB-2V)/≤ 2V
Output current max. 100mA
HRT 46B/66-S122 LEUZE