SICK DBS60E-TBEK01000
SICK DBS60E-TBEK01000
- Performance
Pulses per revolution 1.000 measuring step ≤ 90° electricity/pulses per revolution measurement deviation ± 18° / Pulses per revolution Error limits Deviation in measuring step x 3 Detection degree ≤ 0,5 ± %5
- Interfaces
Communication interface Incremental Communication interface detail HTL / Push pull Number of signal channels 6 channels Start time < 5 ms 1) Output frequency + 300 kHz 2) load current ≤ 30 mA per channel Power consumption ≤ 1 W (No Load) - 1) After this time, valid signals can be read.
- 2) Up to 450 kHz on request.
- electrical data
Connection type Cable, 8-wire, universal, 1.5 m 1) Supply voltage 10 … 27 V Reference signal, number 1 Reference signal, position 90°, electrical, logical combination with A and B Reverse polarization protection ✔ Short-circuit resistance of outputs ✔ 2) MTTFd: Mean time to dangerous failure 500 years (EN ISO 13849-1) 3) - 1) The universal cable connection is positioned so that it can be inserted without kinks in the radial or axial direction.
- 2) Short-circuit allowed against another US channel or GND for a maximum of 30 sec.
- 3) This product is a standard product, it does not contain any safe components defined in the machinery directives. Calculation of structural elements based on nominal load, average ambient temperature 40 °C, frequency of use 8760 h/a. All electronic failures are considered dangerous failures. For detailed information, see Document No. 8015532.
- Mechanical data
Mechanical application Through hollow shaft, Pre-compression Shaft diameter 8 mm Flange type / torque support Torque support 2-sided, long hole, hole circle 63 mm- 83 mm Weight + 0,25 kg 1) Shaft material Stainless steel flange material Aluminum Body material Aluminum cable material PVC Starting torque + 0,5 Ncm (+20 °C) operating torque 0,4 Ncm (+20 °C) Permissible static spindle movement ± 0,3 mm (radyal) ± 0.5 mm (straight) 2)
Permissible dynamic spindle movement ± 0,1 mm (radyal) ± 0.2 mm (straight) 2)
Working speed 6.000 min⁻¹ 3) Maximum number of revolutions 9.000 min⁻¹ 4) moment of inertia of the rotor 50 gcm² Bearing service life 3,6 x 109 tur Angular acceleration ≤ 500.000 rad/s² - 1) Based on encoder with male connector or cable with male connector.
- 2) Does not apply to C and K torque supports.
- 3) Pay attention to self-heating of 2.6 K at 1,000 min⁻¹ when designing the operating temperature range.
- 4) Maximum speed that will not cause mechanical destruction of the encoder. It can affect uptime and signal quality. Please consider the maximum output frequency.